speed range |
1 m/min to ± 4800m/min 1) |
typ. accuracy |
± 0.05 % 2) |
stand-off distance/ depth of field |
120 mm ± 5 mm (± 20 mm) 240 mm ± 10 mm (± 40 mm) 480 mm ± 20 mm (± 80 mm) 3) |
interfaces |
1x RS 485 bi-directional 1x RS 232 (option) 1x interlock (input) 3x differencial TTL I/O freely configurable option - more I/O ports option - diverse Bus-Systems available (Profibus, Device-Net, Ethernet, ...) |
interface configuration |
- quadrature output (A, /A, B, /B) - pulse output - RS 485 - RS 422 - direction - gate - start - status |
communication (option) |
- Profibus - CAN-Bus - EtherNet IP - DeviceNET further communication protocols on demand |
voltage |
24 VDC (option: voltage range 100-230 VAC) |
protection category |
IP 67 |
laser diode |
25mW, 780nm (class 3B) |
dimension (L x H x W) |
154 x 94 x 39 mm |
weight |
1 kg |
|
|
footer |
1) achievable with µSPEED smartsensor S1 to S80 direction by machine signal 2) length L ≥ 5m (1σ); L ≥ 10m (2σ); L ≥ 20m (3σ) 3) values in brackets can cause reduced accuracy |